SV-COM-X83 Installation, Configuration, and Testing
SkyView System Installation Guide - Revision R 17-11
Connect to SV-INTERCOM-2S Pin 25
(Inside shielded cable)
Table 59 - SV-COM-T8 Male D25 Pinout
The following figure depicts how a single SV-COM-T8 is connected to an SV-INTERCOM-2S. Note
that SkyView Network connection(s) on SV-COM-PANEL are not shown, nor are additional
connections between the SV-INTERCOM-2S and other devices that it connects to.
Figure 111 – Single SV-COM-T8 to SV-INTERCOM-2S
Single SV-COM-X83 to SV-INTERCOM-2S Harness Construction Notes
Shielded cable between SV-COM-T8 Pins 2 and 1, and SV-INTERCOM-2S Pins 1 and 14:
This cable consists of two wires plus shield.
Use one of the wires to connect SV-COM-T8 Pin 2 to SV-INTERCOM-2S Pin 14.