VAL Avionics NAV 2000 Installationsanleitung Seite 242

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 401
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 241
SV-ARINC-429 Installation and Configuration
12-2 SkyView System Installation Guide - Revision R
Additional mounting location, orientation, and other installation requirements are described in
the System Planning section earlier in this manual. Please review this section when physically
installing your with SV-ARINC-429 module(s).
Dynon does not provide mounting hardware with SV-ARINC-429 module. The mounting tabs on
each side of the module have holes sized for #10 fasteners, but it is up to the installer to decide
how the SV-ARINC-429 will be secured to the aircraft.
Follow recommended torque practices when tightening the mounting hardware. Do not rivet
the SV-ARINC-429 to the aircraft as this will hinder future removal if necessary.
SkyView Network Connection
Connect the SV-ARINC-429 module to the SkyView network using the hardware mentioned in
the SkyView System Construction Section or using equivalent hardware.
If you have to install a connector on the end of a network cable, insert all pins into the D9
connector. Refer to Appendix C: Wiring and Electrical Connections for details on connector pin-
outs and wire colors.
ARINC-429 Device Connection
Harness Construction
Because the SV-ARINC-429 can be connected to a variety of devices, the harness requirements
will vary from airplane to airplane. Therefore, Dynon Avionics does not supply pre-
manufactured harnesses for the SV-ARINC-429 module. Instead, your SV-ARINC-429 shipped
with enough connectors and pins to generate a wide variety of harness configurations. Refer to
the sections below for detailed wiring information.
If you do not own a D-sub machined-pin crimping tool, they can be obtained for under $50 from
many retailers. See http://wiki.dynonavionics.com/Tools_not_supplied_by_Dynon for known
sources of these products. You may also find it helpful to own a pin insertion/extraction tool as
well.
Additional harness construction and wiring information can be found in Appendix C: Wiring and
Electrical Connections.
The SV-ARINC-429 has a single 25 pin female D-Sub socket which is used for all data
connections to your compatible ARINC-429 device. The pin out depicted in Figure 81 below
depicts the view from the rear of your male D25 connector the view you will have of your
harness connector as you are inserting pins into the harness. Note that the pin numbers are
labelled on the face of both the female and male connector.
Seitenansicht 241