Accessory Installation and Configuration
SkyView System Installation Guide - Revision R 15-7
Heat Status on EMS Page
If an SV-EMS-220 or SV-EMS-221 is installed for engine monitoring, the status of the Heated
Pitot Controller can be displayed on the EMS display.
1. Connect the heater status output wire to the any of the following General Purpose
Inputs that are not already in use: Pins 4, 7, 9, 10, 11. 12, 20, or 21. (General Purpose
Inputs Pins 6, 8, 22, 23, and 31 are more specialized and should be reserved for other
use.)
2. SETUP MENU > EMS SETUP > SENSOR INPUT MAPPING
C37 Px (pin that the heater status output is connected to) set to
CONTACT | CONTACT | PHEAT (or a CUSTOM name of your choice).
3. SETUP MENU > EMS SETUP > SENSOR SETUP > PHEAT CONTACT
ALARM OFF
RANGE 1
ENABLE YES
NAME ON
COLOR GREEN
TOP 5.0V
BOTTOM 2.1V
RANGE 2
ENABLE YES
NAME OFF
COLOR RED
TOP 2.0V
BOTTOM 0.0V
RANGE 3 (and RANGE 4 and RANGE 5)
ENABLE NO
(other parameters are ignored when ENABLE set to NO)
4. SETUP MENU > EMS SETUP > SCREEN LAYOUT EDITOR
SENSOR (button)
Select PHEAT (or custom name) CONTACT
ACCEPT (button)
Adjust size of the icon to your preference.
Adjust location of the icon to your preference.
SAVE (button)
5. Repeat step 5 for 20%, 50%, and 100% layouts as desired
6. Test:
When Pitot Heater Controller is OFF (or fault), EMS screen should display RED indicator
with text OFF.
When Pitot Heater Controller is ON, EMS screen should display GREEN indicator
with text ON.